Versionshinweise –
DataServer for BioWare Utility - 1.6.2.2201
English
Allgemeines
Systemanforderungen
Kompatibilität
Neue Funktionen
Bekannte Probleme
Historie
Allgemeines
This document provides additional
information to the most recent version of the software utilities for the BioWare
DataServer library. This package contains the following items:
- DataServer driver
installation:
The installation of the MCC drivers should be performed before connecting
the type 5691A or 5695A DAQ System devices. For installing the USB drivers follow
the installation instructions.
- The DataServer library is
intended to be integrated with external systems and requires software
programming for proper integration.
- For assistance, refer to the
DataServer.chm file. It contains detailed information and examples of
integration.
Hinweise
- DataServer can be used
stand-alone or together with a BioWare system.
Systemanforderungen
Minimale Systemanforderungen
zum Betrieb der Software
- Windows PC oder Laptop
- Freies USB-Port
- Windows XP, Windows Vista,
Windows 7 (x86 and x64), Windows 8 (x86 and x64)
Kompatibilität
Dieser
Abschnitt zeigt die kompatiblen Hardware- und Software-Konfigurationen.
Keine Abhängigkeiten.
Neue
Funktionen
Changes and fixes for v1.6.2.2201
- 6953: Update to MCC Instacal v6.54
Bekannte
Probleme
Dieser Abschnitt informiert
Sie über bekannte Probleme der aktuellen Version
der Hilfsprogramme dür die BioWare DataServer.
Historie
Changes and fixes for v1.6.1.2198
-
6947:
Cannot get IDaqAdvanced interface from daq object in VS2015.
Changes and fixes for v1.6.0.2197
- 6825:
Board not available message on Win 8.1 after restarting application.
- 6826:
Update to MCC Instacal 6.50 drivers.
Changes and fixes for v1.5.1.2192
- 6583: Support USB-1616HS
as a USB16161FS (no digital).
- 6443: Support MCC 6.31.
Changes and fixes for v1.5.0.2152
- 6443:
Update to MCC Instacal drivers v6.31.
Changes and fixes for v1.4.0.2150
- 5883:
CD-ROM contains incorrect version of MCC drivers.
- 5880:
Update to MCC Instacal drivers v6.25.
Changes and fixes for v1.4.0.2148
- 5848:
Update to MCC Instacal drivers v6.24
- 5852:
Add sample files for C#.
Changes and fixes for 1.3.2.x
- 5547:
Installation did not fully register DataServer.dll COM object for automation
languages
Changes and fixes for 1.3.1.x
- 5434:
PCIM-DAS1602 Time constant control is inverted.
- 5274:
Documenation for IDevice arrVoltage() method contains a typo.
- 5289:
Add method for retrieving safe array of voltages in IDaqControl2.
- 5290:
Ensure channel indexing for IDevice::arrVoltages is based on the device channels.
- 5268:
5695A with external pacer clock - overrun halts system but does not issue
error message.
- 5292:
Add error messages when accessing data no longer in the buffer.
Changes and fixes for
v1.3.0.x
-
3981: 5691 DAQ Box (USB-1616FS) hangs reading offsets.
Requires firmware update to USB-1616FS.
-
5004: Update to support MCC Instacal Version 6.22.
-
3428: C++ Test programs have a compiler error.
Changes and fixes for 1.2.0.x
- 4713: Update to support MCC
Instacal Version 6.20
-
4798: Startup problem when DAQ-5695 is not connected / powered-off.
- 4797:
Support additional DAQ gain settings for 5695.
Changes and fixes for v1.0.4
-
4252 Add Pretriggering
-
4250 Modify log file options
Changes and fixes for v1.0.3
- DAQ 5695 - Acquiring non-sequential plate fails
Changes and fixes for
v1.0.2
-
Minor interface changes to support DAQ 5695 in BioWare
Changes and fixes for
v1.0.1
-
m_DAQ->Running reports 0 when measuring is in progress.
-
Offsets are always read at +/-5V range.
Changes and fixes for
v1.0.0
- Support added for Kistler
64 channel 5695 DAQ System.
- Fixed issue with Offsets
not working properly.
- Removed reading offsets
when Measure is enabled. Requires client to manually call ReadOffsets.
This was done to allow changing between measure on and measure off while data
acquisition is running.
- ReadOffsets method changed
to take A/D Range as a parameter. Usually has the same value as the
range used in the Start method.
Changes and fixes for
v0.9.8
Copyright © 2011, Kistler